YANG Lu, WANG Yuanqing, SHI Yongjiu. FEA of the Loading Capacity of Monolithic Composite Slim Floors with Deep Decks[J]. Journal of Civil and Environmental Engineering, 2008, 30(5): 47-52.
DOI:
YANG Lu, WANG Yuanqing, SHI Yongjiu. FEA of the Loading Capacity of Monolithic Composite Slim Floors with Deep Decks[J]. Journal of Civil and Environmental Engineering, 2008, 30(5): 47-52. DOI: 10.11835/j.issn.1674-4764.2008.05.010.
FEA of the Loading Capacity of Monolithic Composite Slim Floors with Deep Decks
Steelconcrete composite slim floors with the steel beam encased in concrete floor slabs have many advantages
including low structural height
high fire resistance and rapid construction times. These features make such floors a promising for use in multistorey steel buildings. We established a 3D finite element model of a monolithic composite slim floor using the ANSYS software package. We analyzed the loading capacity
deformation behavior
natural vibration frequency
the influence of reinforcement
and the concrete in the floor rib under a uniformly distributed vertical load. We calculated the effective width of midgirder and secondary beams. The following conclusions can be drawn from the analysis results: First
monolithic composite slim floors possess high loading capacity for common buildings. Second
the concrete rib and reinforcement ratio in the rib have significant effects on floor loading capacity. Third
calculation of effective primary beam width should be based on analysis of monolithic floors rather than single beams.