Axial Force in Restrained RC Columns during Heating and Cooling Phases
etc.) were analyzed on axial forces in restrained concrete columns exposed to ISO834 standard fire with cooling phase
compared with those in the standard fire without cooling phase.Based on the simulation results of 2880 cases
a practical calculation method for axial force in column was proposed.It was shown that: (a) for axiallyandrotationally restrained columns in fire with or without cooling phase
the enhancement coefficient of axial force increased gradually first
and then reduced gently or kept constant
and finally decreased quickly.However
in the late stage
the enhancement coefficient corresponding to fire without cooling phase dropped more significant than that with cooling phase; and (b) the influences of the rotational restraint ratio
column length and thickness of concrete cover on the enhancement coefficient of axial force in axiallyandrotationally restrained columns were limited subjected to fire with cooling phase
while the peak value of the enhancement coefficient increased with the increase of the axial restraint ratio
load eccentricity ratio and reinforcement ratio or with the decrease of the load ratio and sectional dimension.