XIANG Yang kai, LAN Xiang yu. Analysis of Impervious Performance about Tunnel Polypropylene Fiber Concrete and the Experimental Comparison[J]. Journal of Civil and Environmental Engineering, 2010, 32(5): 114-118.
DOI:
XIANG Yang kai, LAN Xiang yu. Analysis of Impervious Performance about Tunnel Polypropylene Fiber Concrete and the Experimental Comparison[J]. Journal of Civil and Environmental Engineering, 2010, 32(5): 114-118. DOI: 10.11835/j.issn.1674-4764.2010.05.021.
Analysis of Impervious Performance about Tunnel Polypropylene Fiber Concrete and the Experimental Comparison
most impermeability seudies of polypropylene fiber concrete
as a new sort of tunnel lining waterproof material
are limited to the impervious mechanism and unable to be satisfied with the engineering need. On the basis of fracture mechanics and the micro structure mechanics
the resistance of fiber to the crack extension inside concrete and it’s SIF were deduced
the analytical formula of fiber resistance effect to the opening mode crack extension was presented as well. Meanwhile
the impervious performance of polypropylene fiber concrete was explained reasonably by the numerical calculation of the resistance effect. On the other hand
for comparing the impervious performance of polypropylene fiber concrete with that of UEA concrete
the impervious performance experiments of four groups of different types of concrete were carried out
it is presented that the former is superior to the latter. More than that
adding double polypropylene fiber and UEA to the concrete with proper proportion will make the impervious performance much better.