NIE Shaofeng, ZHOU Tianhua, YUAN Taotao, et al. Experimental Analysis on Behavior of Cold formed Steel Box Built up Section Columns under Axial Compression[J]. Journal of Civil and Environmental Engineering, 2012, 34(4): 46-52.
DOI:
NIE Shaofeng, ZHOU Tianhua, YUAN Taotao, et al. Experimental Analysis on Behavior of Cold formed Steel Box Built up Section Columns under Axial Compression[J]. Journal of Civil and Environmental Engineering, 2012, 34(4): 46-52. DOI: 10.11835/j.issn.1674-4764.2012.04.008.
Experimental Analysis on Behavior of Cold formed Steel Box Built up Section Columns under Axial Compression
17 specimens of cold formed steel box built up setion columns were tested under axial compression load. The section forms were divided into two categories: A and B. Load displacement curves and failure characteristics of specimens were obtained. The test results are compared with the caculated results according to “effective ratio of width to thickness” in code of “Technical code of cold formed thin wall steel structures” (GB 50018-2002)
“effective section method” and “direct strength method” in AISI specification. The results show that: the failure characteristics of LC and MC series columns are overall flexural buckling
while SC series columns are local buckling and ends confined damage. The ultimate bearing capacity of B categories section columns is three times as great as that of A categories section columns
so it has the effect of “1+1>2”. The results calculated according to “GB50018” and AISI specification are much conservative for LC series columns of A categories section
while in agreement with test results for MC and SC series columns. For B categories section columns