Analysis of Polarization Curves Characteristics of Rebar in Concrete
To avoid equilibrium potential shifts in polarization curve test
based on anodic polarization current method
the critical polarization current density of steel corrosion was given as well as the corresponding empirical formula of corrosion current density. Reasonable explanation to equilibrium potential shifts was given by studying polarization curves characteristic of rebar in concrete before and after corrosion. The results show that anodic polarization current method can effectively distinguish steel corrosion
and the critical polarization current density is 0.2 μA/cm 2.