1. 西安建筑科技大学 土木工程学院,西安,710055
3. 河南省电力勘测设计院,郑州,450007
纸质出版:2009
移动端阅览
曹现雷, 郝际平, 曹志民, 等. 高强单角钢一端偏心压杆极限承载力试验研究[J]. 土木与环境工程学报(中英文), 2009,31(5):1-8.
CAO Xianlei, HAO Jiping, CAO Zhimin, et al. Ultimate Bearing Capacity Analysis of HighStrength SingleAngle Compression Member Eccentrically at One End[J]. Journal of Civil and Environmental Engineering, 2009, 31(5): 1-8.
曹现雷, 郝际平, 曹志民, 等. 高强单角钢一端偏心压杆极限承载力试验研究[J]. 土木与环境工程学报(中英文), 2009,31(5):1-8. DOI: 10.11835/j.issn.1674-4764.2009.05.002.
CAO Xianlei, HAO Jiping, CAO Zhimin, et al. Ultimate Bearing Capacity Analysis of HighStrength SingleAngle Compression Member Eccentrically at One End[J]. Journal of Civil and Environmental Engineering, 2009, 31(5): 1-8. DOI: 10.11835/j.issn.1674-4764.2009.05.002.
为了研究输电塔中Q460高强角钢一端偏心压杆受力性能,通过试验与理论计算方法分析了受压试件的整体稳定和局部屈曲情况,试件轴心端采用球铰和双刀口支座模拟,考察了不同端部条件和残余应力等对角钢受力性能的影响,结果表明:试件轴心端无论采用球铰支座或双刀口支座形式,均能较准确反映角钢构件的受力性能,残余应力对试件承载力影响小于5%。比较了试验、有限元法、美国《输电铁塔设计导则》(ASCE 101997)和中国《架空送电线路杆塔结构设计技术规定》(DL/T 51542002)对角钢极限承载力值的不同处理方法,指出采用DL/T 51542002 标准计算方法对高强钢杆件承载力得出的结果偏保守,在此基础上,提出了对实际材料强度除以抗力分项系数rR=1.111后改造的ASCE设计方法。
To analyze mechanical behavior of Q460 highstrength singleangle steel struts with an eccentric load at one end in transmission towers
experimental analysis and theoretical calculation were carried out to study the overall stability and local buckling of members. Spherical hinge bearing and double knifeedge bearing were applied at axial end of specimens. Influence of some factors on bearing capacity of compression members with eccentricities at both ends was analyzed
such as the end supporting conditions and residual stresses. It was shown that whether spherical hinge bearing or double knifeedge bearing was used at axial end
the mechanical behavior can be accurately presented and the residual stresses affected the ultimate loadcarrying capacity by about 5% or less. Compared with different methods
such as experiment method、finite element method
method in the Guide for American Design of Latticed Steel Transmission Structure(ASCE101997)and method in Chinese Technical Regulation of Design for Tower and Pole Structure of Overhead Transmission Line (DL/T51542002)
it was found that the calculated strength of highstrength steel member by standard calculation method in DL/T51542000 was overconservative. According to the research results
the revised formulas of ASCE were proposed with dividing actual material strength by the resistance coefficient of rR=1.111. Therefore
the experimental results can provide reference for designing highstrength Q460 singleangle steel members compressed eccentrically at one end.