Optimization of cooling air supply in room air conditioners for improved indoor thermal uniformity
更新时间:2025-12-16
    • Optimization of cooling air supply in room air conditioners for improved indoor thermal uniformity

    • “In the field of indoor environmental quality, experts have proposed a dual layer near far circulation air supply method based on ultra-low Mach number cyclone and annular rotating jet technology, which effectively improves the indoor temperature uniformity of room air conditioners and is particularly suitable for meeting the needs of the elderly population for stable, comfortable, and low irritant thermal environments.”
    • Journal of Civil and Environmental Engineering   Pages: 1-13(2025)
    • DOI:10.11835/j.issn.2096-6717.2025.102    

      CLC: TU831.6
    • Received:14 May 2025,

      Online First:16 December 2025,

    移动端阅览

  • QIU Xiangwei,ZHAI Yingxian,LIU Zhilong,et al.Optimization of cooling air supply in room air conditioners for improved indoor thermal uniformity[J].Journal of Civil and Environmental Engineering, DOI:10.11835/j.issn.2096-6717.2025.102.

  •  
  •  

0

Views

1

下载量

0

CSCD

Alert me when the article has been cited
提交
Tools
Download
Export Citation
Share
Add to favorites
Add to my album

Related Articles

Study on urban outdoor thermal comfort of pedestrian space in hot-humid area in summer
Measurement and analysis of winter indoor thermal environment of facility room in subway stations in Kunming
Analysis of temperature setting habits of room air conditioners in the typical cities in Yangtze River Basin under the big data monitoring platform
Indoor thermal comfort range of naturally ventilated sports buildings in the subtropical regions
Experimental analysis on three kinds of bed/kang heating method in rural houses at night

Related Author

Lihua Zhao
Qinglin Meng
Yi Jiang
Xuan He
Yuan Luo
Meng Liu
Mengqiang Hu
Zhenkun Xu

Related Institution

No data
0